In these cases if the receptacle is too sunken in and set back from the wall, I will take a small piece of solid copper wire and wrap it around the receptacles' mounting screw to act as a small spacer so it is at the right position. Junction boxes enclose wire connections without making the power available to the user.

plaster rings for electrical boxes

It is possible that due to varying wall thicknesses (plaster patches from olden days, skim coats, etc.) that in some instances the mud ring will not be flush with the wall, but may be set back 1/8 - 3/16" at most.

#PLASTER RINGS FOR ELECTRICAL BOXES PATCH#

I am told to patch with joint compound all around the box and right up to the sharp mud ring’s edge…therefore the box will be neatly ‘embedded” in compound and flush with the wall. The mud ring’s most prominent forward edge is a thin edge…from there is curves back towards the actual recep box. Now I need to patch around the recep box, as cutting into plaster walls is a huge messy enterprise and has no relationship to cutting into sheetrock. With the metal 3/4” mud ring screwed to the metal recep box, the assembly is nearly flush with the wall, or is set back only about 1/8” at most. Raised Device Covers are Used for Mounting Switches or Receptacles Low Voltage Partitions May be Added to Conduit Type Boxes to Divide. The electrical supply stores here (even specialty electric) didn't have a clue about adjustable boxes, or lathing specific boxes for this purpose, and sold me the mud ring. describing plaster rings / mud rings (and mentioning issue with installing covers on boxes that are not grounded).See also. Because there’s a large gap between the box and the wall’s outer surface, I need to bring the box further forward. I have recep quad boxes with the mounting flange that goes over the lathing. Our mud ring covers have an easy snap-in fit to protect outlets from.

#PLASTER RINGS FOR ELECTRICAL BOXES FULL#

First there are the wood 2x4 studs (oriented with the wide side facing the room, not the narrow side as in new sheetrock construction), then on top of the studs are rough 1/4” or so thick wood lathing strips, then there’s a full 1” of various layers of plaster. SmartGuards clear plastic mud ring covers protect wiring & plug tail applications. Exception: A vertically mounted luminaire or lampholder weighing not more than 3 kg (6 lb) shall be permitted to be supported on other boxes or plaster rings. The wall is plaster/wood lathe construction.

plaster rings for electrical boxes

Our products have evolved over the years with input from local electricians and end-users. Octagon box plaster or mud rings are used with octagon electrical box and they are designed to help give electrical contractors greater job site flexibility by. After you have cut out the hole for the mud ring just place it in and bend the tabs back into the wall and then cinch down the tabs with a pair of pliers to make sure it stays in place.Click to expand.J.V., can you clarify: your post appears to contradict with what Bob says upthread.Ī pic is worth 1,000 words, but let me try to be clearer. With over 100 years of experience, Iberville steel boxes and covers are proudly designed and manufactured in Canada using Canadian-sourced raw material. The first cut should be done laterally because if you run into a stud you can just go back the other direction if you were to cut vertically first then cut laterally you would have to start all over and end up with an ugly saw mark on the wall.

#PLASTER RINGS FOR ELECTRICAL BOXES INSTALL#

To install this unit into a wall place the plaster ring on the wall where you need it, it’s a good idea to measure where the rest of the wall plates are situated on the wall and mimic this height for uniformity, and mark each corner with your drywall saw. In walls and ceilings constructed of wood or other combustible surface material, boxes, plaster rings, extension rings, or listed extenders shall be flush. The Erico Plaster Ring, also called a mud ring, eliminates the need for an electrical box when installing low voltage Class 2 wiring. Erico Plaster Ring / Mud Ring (Commercial Grade).